Summary
Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions.
The following versions of Siemens Siveillance Video are affected:
- Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014)
- Siveillance Video V2024 R1 vers:intdot/<24.1.16 (CVE-2026-3014)
- Siveillance Video V2025 vers:intdot/<25.1.15 (CVE-2026-3014)
| CVSS | Vendor | Equipment | Vulnerabilities |
|---|---|---|---|
| v3 9.1 | Siemens | Siemens Siveillance Video | Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') |
Background
- Critical Infrastructure Sectors: Critical Manufacturing, Communications, Commercial Facilities
- Countries/Areas Deployed: Worldwide
- Company Headquarters Location: Germany
Vulnerabilities
CVE-2026-3014
Milestone has released a new version of XProtect® (and several cumulative patch updates) which fix security vulnerability in Management Server API. The vulnerability causes users with edit permissions to the Management Server to be able to execute arbitrary code in context of the Management Server Service.
Affected Products
Siemens Siveillance Video
Siemens
Siveillance Video V2023 R3 < V23.3.27, Siveillance Video V2024 R1 < V24.1.16, Siveillance Video V2025 < V25.1.15
known_affected
Remediations
Vendor fix
Update to V23.3 HotfixRev27 or later version
https://support.industry.siemens.com/cs/ww/en/view/109827783/
Vendor fix
Update to V24.1 HotfixRev16 or later version
https://support.industry.siemens.com/cs/ww/en/view/109976123/
Vendor fix
Update to V25.1 HotfixRev15 or later version
https://support.industry.siemens.com/cs/ww/en/view/109988670/
Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Metrics
| CVSS Version | Base Score | Base Severity | Vector String |
|---|---|---|---|
| 3.1 | 9.1 | CRITICAL | CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H |
Acknowledgments
- Milestone PSIRT reported this vulnerability to Siemens
General Recommendations
As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use
Legal Notice and Terms of Use
This product is provided subject to this Notification (https://www.cisa.gov/notification and this Privacy & Use policy (https://www.cisa.gov/privacy-policy
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
Advisory Conversion Disclaimer
This ICSA is a verbatim republication of Siemens SSA-825228 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory.
Revision History
- Initial Release Date: 2026-08-11
| Date | Revision | Summary |
|---|---|---|
| 2026-08-11 | 1 | Publication Date |
| 2026-08-13 | 2 | Initial CISA Republication of Siemens SSA-825228 advisory |
Legal Notice and Terms of Use
This product is provided subject to this Notification and this Privacy & Use policy.
Vendor
- Siemens
